1101:Zmin限位开关在归位时没有触发
Zmin endstop not pressed after homing down.
1102:Zmin或者Zoffset限位开关在归位后退时仍然触发
Zmin or Zoffset endstop still pressed after backing off.
1103:Xmax或者Ymax限位开关在归位时没有触发
Xmax or Ymax endstop not pressed after homing down.
1104:Xmin限位开关在归位后退时仍然触发
Xmin endstop still pressed after backing off.
1105:Xmax限位开关在归位后退时仍然触发
Xmax endstop still pressed after backing off.
1106:Ymin限位开关在归位后退时仍然触发
Ymin endstop still pressed after backing off.
1107:Ymax限位开关在归位后退时仍然触发
Ymax endstop still pressed after backing off.
1108:Zmin限位开关在归位后退时仍然触发
Zmin endstop still pressed after backing off.
1109:Zmax限位开关在归位后退时仍然触发
Zmax endstop still pressed after backing off.
原因:各处限位开关由于短路、短路或者对应的连接线等发生故障
解决意见:
1、检查打印机中是否有异物阻塞导致打印机无法正常运动。
2、在非打印状态时,用工具触发对应错误代码指出的限位开关(每一个开关都对应了一个指示灯),观察对应开关指示灯是否正常亮灭(按下亮,松开灭)。如果没正常亮灭,可能原因是连接开关的排线损坏或接触不良,重新拔插后进行测试。也可能是对应开关损坏,联系售后进行更换维护。
3、确认是否为开关损坏,联系售后更换。